Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 23
Filter
1.
Braz. dent. j ; 33(5): 108-115, Sep.-Oct. 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1403780

ABSTRACT

Abstract Non-carious Cervical Lesions (NCCL) are dental tissue defects, non-related to caries, frequently observed in the dental practice. The aim of this study was to evaluate the effects of NCCL on dentin depth and thickness and the response to dental pain by means of clinical diagnostic tests. 86 teeth from 14 patients with NCCL were assessed by: depth of NCCL, clinical tests (evaporative stimulus, to detect pain levels of dentin hypersensitivity, cold thermal test to classify pulp health, percussive stimuli to evaluate the periradicular tissues and cone beam computed tomography (tomography to evaluate remaining dentin thickness (RDT). In terms of depth, the sample was divided into two groups: G1- teeth with NCCLs ≤1.0mm and G2- teeth with NCCLs between 1.1-2.0 mm. Dental pain data were compared by Mann-Whitney test and RDT by Student's t-test and correlations by the Pearson test (p<0.05). The depth of NCCL does not influence dental pain response to evaporative stimulus (p=0.129), cold thermal test (p = 0.125), vertical (p = 0.317) and horizontal (p = 0.119) percussion clinical diagnostic tests. However, G1 showed more RDT (p<0.001), and the correlation test showed that deeper NCCL presents smaller remaining dentin thickness (p=0.011/r=-0.273). In conclusion, tooth with NCCL up to 2mm-depth presents similar levels of pain for dentin hypersensitivity, pulp and periradicular tissue independent to NCCL depth, however, lesions with ≤1.0mm-depth showed greater RDT in tomographic findings.


Resumo Lesões Cervicais Não Cariosas (LCNC) são defeitos do tecido dentário, não relacionados à cárie, frequentemente observados na prática odontológica. O objetivo do estudo foi avaliar os efeitos da profundidade e espessura da dentina de LCNC na resposta à dor dentária por meio de testes de diagnóstico clínico. 86 dentes de 14 pacientes com LCNC foram avaliados por: profundidade da LCNC, testes clínicos (estímulo evaporativo, para detectar níveis de dor de hipersensibilidade dentinária, teste térmico frio para classificar a saúde pulpar, estímulos percussivos para avaliação do tecido perirradicular e tomografia computadorizada de feixe cônico (TCFC), para avaliação da espessura de dentina remanescente (EDR). Em termos de profundidade, a amostra foi dividida em dois grupos: G1- dentes com LCNCs ≤1,0mm e G2- dentes com LCNCs entre 1,1-2,0 mm. Os dados de dor dentária foram comparados pelo teste de Mann-Whitney e a EDR pelo teste t-Student e correlações pelo teste de Pearson (p <0,05). A profundidade da LCNC não influencia a resposta da dor dentária ao estímulo evaporativo (p = 0,129, teste térmico frio (p = 0,125), teste diagnóstico clínico de percussão vertical (p = 0,317) e horizontal (p = 0,119), porém o G1 apresentou maior EDR (p <0,001) e o teste de correlação mostrou que LCNC mais profunda apresenta menor EDR (p = 0,011 / r = -0,273). Conclusão: Dentes com LCNC de até 2mm de profundidade apresenta níveis semelhantes de dor para hipersensibilidade dentinária, pulpar e saúde perirradicular, independente da profundidade da LCNC. Entretanto, lesões com profundidade ≤1,0mmin apresentaram mais EDR nos achados tomográficos.

2.
Dental press j. orthod. (Impr.) ; 27(5): e2220325, 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1404497

ABSTRACT

ABSTRACT Introduction: Many patients wearing orthodontic appliances request alterations in the shade of their teeth during orthodontic treatment. Objective: This study aimed to evaluate the efficacy of different products for bleaching and whitening under orthodontic brackets. Methods: Seventy bovine incisors were randomly divided into five groups (n = 14): C) non-whitening toothpaste (control); WTsi) hydrated silica whitening toothpaste; WThp) 2% hydrogen peroxide whitening toothpaste; OB) in-office bleaching; and HB) at-home bleaching. Two buccal surface areas were evaluated using the Easyshade spectrophotometer: under the metal bracket (experimental) and around the bracket (control). The paired t-test, ANOVA, and Tukey tests were applied for statistical analysis. Results: Intragroup comparisons showed that in groups C, WThp and HB, there were statistically significant differences in the enamel color changes (ΔEab) between under and around the bracket areas (C - under bracket = 7.97 ± 2.35, around bracket = 2.86 ± 0.81, p< 0.01; WThp - under bracket = 4.69 ± 2.98, around bracket = 2.05 ± 1.41, p< 0.01; HB - under bracket = 7.41 ± 2.89, around bracket: 9.86 ± 3.32, p= 0.02). Groups WTsi, OB and HB presented similar perception of tooth whiteness (ΔWID) between the tested areas. Intergroup comparisons demonstrated that under the bracket area, the color change (ΔEab) was similar for all groups, except WThp (C = 7.97 ± 2.35; WTsi = 8.54 ± 3.63; WThp = 4.69 ± 2.98; OB = 9.31 ± 4.32; HB = 7.41 ± 2.89; p< 0.01). Conclusions: The dental color changes were effective for the products tested in groups WTsi, OB and HB in the presence of metallic orthodontic brackets.


RESUMO Introdução: Durante o tratamento ortodôntico, muitos pacientes solicitam, também, alteração na cor dos seus dentes. Objetivo: O presente estudo avaliou diferentes produtos clareadores e branqueadores, quanto à sua eficácia sob os braquetes ortodônticos. Métodos: 70 incisivos bovinos foram aleatoriamente divididos em cinco grupos (n = 14): C) dentifrício não branqueador (controle); WTsi) dentifrício branqueador com sílica hidratada; WThp) dentifrício branqueador com peróxido de hidrogênio a 2%; OB) clareamento no consultório e HB) clareamento caseiro. Usando um espectrofotômetro Easyshade, foram avaliadas duas áreas na superfície vestibular dos dentes: sob o braquete (experimental) e ao redor do braquete (controle). Para análise estatística, foram usados os testest pareado, ANOVA e Tukey. Resultados: As comparações intragrupos demonstraram que, nos grupos C, WThp e HB, ocorreram diferenças estatisticamente significativas nas alterações de cor do esmalte (ΔEab) entre as áreas sob o braquete e ao redor do braquete (C: sob o braquete = 7,97 ± 2,35, ao redor do braquete = 2,86 ± 0,81, p< 0,01; WThp: sob o braquete = 4,69 ± 2,98, ao redor do braquete = 2,05 ± 1,41, p< 0,01; HB: sob o braquete = 7,41 ± 2,89, ao redor do braquete = 9,86 ± 3,32, p= 0,02). Os grupos WTsi, OB e HB demonstraram semelhanças na percepção do clareamento (ΔWID) entre as áreas avaliadas. As comparações intergrupos demonstraram que, nas áreas sob os braquetes, as alterações de cor (ΔEab) foram semelhantes para os grupos, com exceção do WThp (C = 7,97 ± 2,35; WTsi = 8,54 ± 3,63; WThp = 4,69 ± 2,98; OB = 9,31 ± 4,32; HB = 7,41 ± 2,89; p< 0,01). Conclusões: As alterações na cor dos dentes foram efetivas para os procedimentos testados nos grupos WTsi, OB e HB na presença de braquetes metálicos ortodônticos.

3.
Braz. oral res. (Online) ; 36: e006, 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1355933

ABSTRACT

Abstract The aim of this scoping review was to provide sufficient information about the effectiveness of ozone gas in virus inactivation of surfaces and objects under different environmental conditions. The review was performed according to the list of PRISMA SrC recommendations and the JBI Manual for Evidence Synthesis for Scoping Reviews. The review was registered in Open Science Framework (OSF). EMBASE (Ovid), Lilacs, LIVIVO, MEDLINE (PubMed), SciELO, Scopus and Web of Science were primary sources, and "gray literature" was searched in OpenGray and OpenThesis. A study was included if it reported primary data on the effect of ozone gas application for vehicle-borne and airborne virus inactivation. No language or publication date restriction was applied. The search was conduct on July 1, 2020. A total of 16,120 studies were screened, and after exclusion of noneligible studies, fifteen studies fulfilled all selection criteria. Application of ozone gas varied in terms of concentration, ozone exposure period and the devices used to generate ozone gas. Twelve studies showed positive results for inactivation of different virus types, including bacteriophages, SARS-CoV-2 surrogates and other vehicle-borne viruses. Most of the studies were classified as unclear regarding sponsorship status. Although most of the population has not yet been vaccinated against COVID-19, disinfection of environments, surfaces, and objects is an essential prevention strategy to control the spread of this disease. The results of this Scoping Review demonstrate that ozone gas is promising for viral disinfection of surfaces.

4.
Braz. dent. j ; 32(4): 19-30, July-Aug. 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1345519

ABSTRACT

Abstract: This study investigated the bleaching effectiveness and the physicochemical effects on enamel of violet light and ozone, associate or not to hydrogen peroxide, compared to 35%-hydrogen peroxide. Enamel-dentin blocks from human molars were randomly allocated to receive one of the following bleaching protocols (n=15): (HP) 35%-hydrogen peroxide, (VL) violet light, (OZ) ozone, the association between hydrogen peroxide with ozone (OZ+HP) or violet light (VL+HP). All protocols were performed in two sessions with a 48h interval. Color (spectrophotometer) and mineral composition (Raman spectroscopy) were measured before and after the bleaching. Color changes were calculated by ΔEab, ΔE00, and whitening index (WI). The surface roughness was measured with an atomic force microscope. Data were analyzed by One-way or Two-way repeated measure ANOVA followed by the Tukey's test (α = 0.05). The lowest color change values (either measured by WI, ΔEab, or ΔE00) were observed for VL and OZ used with no HP. Violet light associate with HP was unable to improve the color changes observed for the peroxide alone, in combination with OZ and HP, the highest color changes were verified. Regardless of bleaching protocol, the bleached enamel presented higher contents of PO4 and CO3 -2 than those observed at baseline. All bleaching protocols resulted in similar enamel surface roughness. Both the VL and the OZ caused reduced effects on the enamel color change when used alone. The ozone therapy improved the bleaching effect in the group that received the association of HP.


Resumo O objetivo deste estudo foi avaliar o efeito clareador e físico-químico no esmalte de luz violeta e ozônio, associado ou não ao peróxido de hidrogênio, comparado a 35% de peróxido de hidrogênio. Blocos de esmalte-dentina de molares humanos foram alocados aleatoriamente para receber um dos seguintes protocolos de clareamento (n = 15): (HP) peróxido de hidrogênio a 35%, (VL) luz violeta, (OZ) ozônio, a associação entre peróxido de hidrogênio com ozônio (HP+OZ) ou luz violeta (HP+VL). Todos os protocolos foram realizados em duas sessões, com intervalo de 48 horas entre eles. A cor (espectrofotômetro) e a composição mineral (espectroscopia Raman) do dente foram medidas antes e após os procedimentos de clareamento. As alterações de cor foram calculadas por ΔEab e ΔE00, e o índice de brancura foram calculados. A rugosidade da superfície das amostras clareadas foi medida por microscópio de força atômica. Os dados foram analisados por ANOVA One way ou ANOVA two way de medidas repetidas seguida pelo teste de Tukey (α = 0,05). Os menores valores de alterações de cor (medidos por WI, ΔEab ou ΔE00) foram observados para VL e OZ usados na ausência de HP. VL associada ao HP não foi capaz de melhorar as alterações de cor observadas com o uso do HP, mas a combinação de OZ e HP produz as maiores alterações de cor. Independentemente do protocolo de clareamento, o esmalte clareado apresentou maiores teores de PO4 e CO3 -2 do que os observados inicialmente. Não foi observada diferença significativa entre os protocolos de clareamento testados em relação à rugosidade da superfície do esmalte. É possível concluir que a VL ou o OZ tiveram efeitos reduzidos na mudança de cor do esmalte quando usados sozinhos. A terapia com OZ melhorou o efeito clareador do HP.


Subject(s)
Humans , Ozone , Tooth Bleaching , Tooth Bleaching Agents , Color , Dental Enamel , Hydrogen Peroxide
5.
Article | IMSEAR | ID: sea-210674

ABSTRACT

Ocular toxoplasmosis is caused by Toxoplasma gondii, inducing retinochoroiditis. It is the leading cause of infectiousposterior uveitis worldwide. Its treatment is based on oral drug administration. However, the blood–ocular barriersystems make the penetration of therapeutic drug concentrations within the eye difficult, limiting the effectiveness oftreatments. In this context, ocular drug delivery systems represent therapeutic alternative for the treatment of oculartoxoplasmosis. In this study, a review of clinical manifestations, diagnosis, treatment, and perspectives regardingthe treatment of ocular toxoplasmosis was conducted. A search was carried out on ScienceDirect, Scopus, Webof Science, PubMed, and SciELO, and the following keywords were used: toxoplasmosis, ocular toxoplasmosis,toxoplasmic retinochoroiditis, and congenital toxoplasmosis; and Boolean operators, associated with other keywords,such as epidemiology, ocular toxoplasmosis diagnosis, ocular toxoplasmosis treatment, and ocular toxoplasmosisperspectives, were applied. In conclusion, ocular toxoplasmosis still lacks effective treatment. Therefore, it is essentialto develop new molecules and/or new drug delivery systems capable of releasing therapeutic doses of anti-Toxoplasmadrugs directly in the posterior segment of the eye, for an extended period, since complications resulting from thedisease may shorten the productive life of individuals and may even lead to blindness

6.
Braz. dent. j ; 28(5): 624-631, Sept.-Oct. 2017. tab, graf
Article in English | LILACS | ID: biblio-888690

ABSTRACT

Abstract The aim of this study was to evaluate the degree of conversion, color stability, chemical composition, and bond strength of a light-cured resin cement contaminated with three different hemostatic solutions. Specimens were prepared for the control (uncontaminated resin cement) and experimental groups (resin cement contaminated with one of the hemostatic solutions) according to the tests. For degree of conversion, DC (n = 5) and color analyses (n = 10), specimens (3 mm in diameter and 2 mm thick) were evaluated by Fourier transform infrared spectroscopy (FTIR) and CIELAB spectrophotometry (L*, a*, b*), respectively. For elemental chemical analysis (n = 1), specimens (2 mm thick and 6 mm in diameter) were evaluated by x-ray energy-dispersive spectroscopy (EDS). The bond strengths of the groups were assessed by the microshear test (n = 20) in a leucite-reinforced glass ceramic substrate, followed by failure mode analysis by scanning electron microscopy (SEM). The mean values, except for the elemental chemical evaluation and failure mode, were evaluated by ANOVA and Tukey's HSD test. The color stability was influenced by storage time (p<0.001) and interaction between contamination and storage time (p<0.001). Hemostop and Viscostat Clear contamination did not affect the DC, however Viscostat increased the DC. Bond strength of the resin cement to ceramic was negatively affected by the contaminants (p<0.001). Contamination by hemostatic agents affected the bond strength, degree of conversion, and color stability of the light-cured resin cement tested.


Resumo O objetivo desse estudo foi avaliar o grau de conversão, estabilidade de cor, composição química e resistência de união de um cimento resinoso fotoativado contaminado com três soluções hemostáticas diferentes. Foram preparadas amostras para o grupo controle (cimento não contaminado) e grupos experimentais (cimento contaminado com uma das soluções hemostáticas) de acordo com os testes. Para o grau de conversão e análise de cor (n=10), as amostras (3 mm de diâmetro e 2 mm de espessura) foram avaliadas por espectroscopia de infravermelho com transformação de Fourier (FTIR) e espectrofotometria CIELAB (L*, A*, B*), respectivamente. Para a análise química elementar (n=1), os espécimes (2 mm de espessura e 6 mm de diâmetro) foram avaliados por espectroscopia de energia dispersiva de raios-x (EDS). As resistências de união dos grupos foram avaliadas pelo ensaio de microcisalhamento (n=20) em um substrato cerâmico de vidro reforçado com leucita, seguida da análise de modo de falha por microscopia eletrônica de varredura (MEV). Os valores médios, com exceção da avaliação química e do modo de falha, foram avaliados por ANOVA e pelo teste de Tukey. A estabilidade de cor foi influenciada pelo tempo de armazenagem (p<0,001) e interação entre a contaminação e o tempo (p<0,001). A contaminação pelo Hemostop e Viscostat Clear não influenciaram no GC, porém a contaminação com Viscostat aumentou o GC. A resistência de união do cimento a cerâmica foi negativamente afetada pelos contaminantes (p<0,001). A contaminação por agentes hemostáticos afetou a resistência de união, o grau de conversão e a estabilidade de cor do cimento resinoso fotoativado testado.


Subject(s)
Hemostatics , Resin Cements/chemistry , Color , Microscopy, Electron, Scanning , Solutions , Spectrum Analysis , Surface Properties
7.
Braz. dent. j ; 28(3): 362-371, May-June 2017. tab, graf
Article in English | LILACS | ID: biblio-888649

ABSTRACT

Abstract This study measured the radiant power (mW), irradiance (mW/cm2) and emission spectra (mW/cm2/nm) of 22 new, or almost new, light curing units (LCUs): - Alt Lux II, BioLux Standard, Bluephase G2, Curing Light XL 3000, Demetron LC, DX Turbo LED 1200, EC450, EC500, Emitter C, Emitter D, KON-LUX, LED 3M ESPE, Led Lux II, Optilight Color, Optilight Max, Optilux 501, Poly Wireless, Radii cal, Radii plus, TL-01, VALO Cordless. These LCUs were either monowave or multiple peak light emitting diode (LED) units or quartz-tungsten-halogen LCUs used in anterior and posterior teeth. The radiant power emitted by the LCUs was measured by a laboratory grade laser power meter. The tip area (cm²) of the LCUs was measured and used to calculate the irradiance from the measured radiant power source. The MARC-Patient Simulator (MARC-PS) with a laboratory grade spectrometer (USB4000, Ocean Optics) was used to measure the irradiance and emission spectrum from each LCU three times at the sensor located on the facial of the maxillary central incisors and then separately at the occlusal of a maxillary second molar. The minimum acceptable irradiance level was set as 500 mW/cm2. Irradiance data was analyzed using two-way ANOVA and the radiant power data was analyzed by one-way ANOVA followed by Tukey test (a=0.05). In general, the irradiance was reduced at the molar tooth for most LCUs. Only the Valo, Bluephase G2 and Radii Plus delivered an irradiance similar to the anterior and posterior sensors greater than 500 mW/cm2. KON-LUX, Altlux II, Biolux Standard, TL-01, Optilux 501, DX Turbo LED 1200 LCUs delivered lower irradiance values than the recommended one used in molar region, KON-LUX and Altlux II LCUs used at the maxillary incisors. Bluephase G2 and Optilight Max delivered the highest radiant power and KON-LUX, Altlux II and Biolux Standard delivered the lowest power. The emission spectrum from the various monowave LED LCUs varied greatly. The multi-peak LCUs delivered similar emission spectra to both sensors.


Resumo Este estudo mediu a potência (mW), irradiância (mW/cm2) e espectro da luz (mW/cm2/nm) emitida por 22 fontes de luz (Alt Lux II, BioLux Standard, Bluephase G2, Curing Light XL 3000, Demetron LC, DX Turbo LED 1200, EC450, EC500, Emitter C, Emitter D, KON-LUX, LED 3M ESPE, Led Lux II, Optilight Color, Optilight Max, Optilux 501, Poly Wireless, Radii cal, Radii plus, TL-01, VALO Cordless) disponíveis comercialmente. A potência emitida pelas fontes de luz foi medida usando um medidor laboratorial de potencia com grade a laser. A área (cm²) da ponta ativa efetiva das fontes de luz foi medida com paquímetro digital e utilizada para calcular a irradiância emitida. O simulador de paciente-MARC (MARC - PS) com espectrómetro (USB4000, Ocean Optics) foi usado para medir a irradiância e o espectro de luz emitida por cada fonte de luz na região anterior e posterior. Esta medição foi repetida por três vezes em dois sensores localizados na região anterior e posterior da arcada dentária. Os dados de irradiância foram analisados utilizando análise de variância em dois fatores, e os dados de potência foram analisados com análise de variância em fator único seguido pelo teste de Tukey (a=0,05). As fontes de luz Valo, Bluephase G2, Radii Plus emitiram irradiância semelhante tanto na região anterior como posterior com valores superiores ao mínimo de 500 mW/cm2. Seis fontes de luz emitiram irradiância menor que o recomendado (500 mW/cm2) quando usadas na região posterior: Kon-lux, Altlux II, Biolux Standard TL-01, Optilux 501, DX Turbo LED 1200 e duas quando usadas na região anterior: Kon-lux e Altlux II LCUs. As fontes Bluephase G2, Optilight Max emitiram os maiores valores de potência e as fontes de luz Altlux II e Biolux Standard emitiram os menores valores de potência. O espectro de luz das fontes LED de espectro único variou de forma evidente entre as fontes. As fontes LED multi pico de espectro emitiram espectros de luz similar para ambos os sensores. A fotoativação na região posterior tende a reduzir substancialmente a irradiância da maioria das fontes de luzes testadas.


Subject(s)
Humans , Curing Lights, Dental , Dental Restoration, Permanent , Lasers , Patient Simulation , Spectrum Analysis/instrumentation , Tooth/radiation effects
8.
Braz. oral res. (Online) ; 30(1): e3, 2016. tab, graf
Article in English | LILACS | ID: lil-768254

ABSTRACT

We analyzed the effect of the crosshead speed of an applied load on failure load and failure mode of restored human premolars. Fifty intact, noncarious human premolars were selected. Class II mesio-occlusodistal preparations were made with a water-cooled high-speed preparation machine, and the teeth were restored with composite resin. The specimens were divided into five groups (n = 10 each) and tested individually in a mechanical testing machine, in which a 6.0-mm-diameter steel cylinder was mounted to vary the crosshead speed: v0.5: 0.5 mm/min; v1: 1.0 mm/min; v2.5: 2.5 mm/min; v5: 5.0 mm/min; and v10: 10.0 mm/min. The cylinder contacted the facial and lingual ridges beyond the margins of the restorations. Peak load to fracture was measured for each specimen (N). The means were calculated and analyzed with one-way analysis of variance followed by Tukey's test (a = 0.05). The mean load at failure values were (N) as follows: v0.5, 769.4 ± 174.8; v1, 645.2 ± 115.7; v5, 614.3 ± 126.0; v2.5, 609.2 ± 208.1; and v10, 432.5 ± 136.9. The fracture modes were recorded on the basis of the degree of the tooth structural and restorative damage: (I) fracture of the restoration involving a small portion of the tooth; (II) fractures involving the coronal portion of the tooth with cohesive failure of the composite resin; (III) oblique tooth and restoration fracture with periodontal involvement; and (IV) vertical root and coronal fracture. Varying crosshead speeds of 0.5–5.0 mm/min did not influence the failure load of restored maxillary premolars; however, increasing the crosshead speed to 10 mm/min decreased the failure load values and the degree of tooth structural damage.


Subject(s)
Humans , Bicuspid , Dental Restoration Failure , Dental Restoration, Permanent/methods , Tooth Fractures/etiology , Analysis of Variance , Biomechanical Phenomena , Composite Resins/chemistry , Dental Stress Analysis , Dental Cavity Preparation/methods , Dental Restoration, Permanent/instrumentation , Random Allocation , Reference Values , Statistics, Nonparametric , Stress, Mechanical , Tensile Strength , Time Factors
9.
Braz. dent. j ; 25(4): 327-331, 2014. tab, graf
Article in English | LILACS | ID: lil-722604

ABSTRACT

The aim of this study was to evaluate the microtensile bond strength (µTBS) of two substrates (enamel and dentin) considering two study factors: type of composite resin [methacrylate-based (Filtek Supreme) or silorane-based (Filtek LS)] and aging time (24 h or 3 months). Twenty human molars were selected and divided into 2 groups (n=10) considering two dental substrates, enamel or dentin. The enamel and dentin of each tooth was divided into two halves separated by a glass plate. Each tooth was restored using both tested composite resins following the manufacturer's instructions. The samples were sectioned, producing 4 sticks for each composite resin. Half of them were tested after 24 h and half after 3 months. µTBS testing was carried out at 0.05 mm/s. Data were analyzed by three-way ANOVA and Tukey's HSD tests at α=0.05. Significant differences between composite resins and substrates were found (p<0.05), but no statistically significant difference was found for aging time and interactions among study factors. The methacrylate-based resin showed higher µTBS than the silorane-based resin. The µTBS for enamel was significantly higher than for dentin, irrespective of the composite resin and storage time. Three months of storage was not sufficient time to cause degradation of the bonding interaction of either of the composite resins to enamel and dentin.


O objetivo deste estudo foi avaliar a resistência adesiva por meio do teste de microtração (µTBS) entre dois substratos (esmalte e dentina) considerando dois fatores em estudo: Tipo de resina [metacrilato (Filtek Supreme) ou silorano (Filtek LS)] e tempo de envelhecimento (24 horas ou 3 meses). Vinte molares humanos foram selecionados e divididos em dois grupos (n=10) considerando dois substratos dentários, esmalte e dentina. O esmalte e a dentina de cada dente foram divididos em duas metades, por meio de uma lamínula. Cada dente foi restaurado usando ambas as resinas testadas, seguindo instruções do fabricante. As amostras foram seccionadas, resultando em quatro palitos para cada tipo de resina. Metade dos palitos foi testada após 24h e o restante após três meses. O ensaio de microtração (µTBS) foi conduzido numa velocidade de 0,05 mm/s. Os dados foram analisados usando three-way ANOVA e teste de Tukey HSD (α= 0,05). Diferença significante foi encontrada para o fator resina e substratos (p<0,05), porém não houve influência do tempo de envelhecimento e interações entre fatores estudados. A resina à base de metacrilato apresentou maior resistência adesiva do que a silorano. A adesão em esmalte foi significativamente maior do que em dentina, independente da resina e do tempo de envelhecimento. Três meses de armazenamento não foram suficientes para causar degradação da interação adesiva, para ambas as resinas compostas, no esmalte e na dentina.


Subject(s)
Humans , Dental Enamel , Dentin , Methacrylates , Silorane Resins , Tensile Strength , In Vitro Techniques
10.
UNOPAR Cient., Ciênc. biol. saude ; 14(4): 251-256, out. 2012. ilus
Article in Portuguese | LILACS-Express | LILACS | ID: lil-655273

ABSTRACT

Mudanças nos padrões de beleza estimulam cada vez mais pessoas a procurar tratamento odontológico com resultado estético de alta excelência. O objetivo deste artigo foi abordar diferentes técnicas restauradoras diretas para fraturas coronárias de dentes anteriores traumatizados, enfatizando os protocolos clínicos, suas vantagens e desvantagens. Dessa forma, três relatos de casos são ilustrados e discutidos. Na primeira situação clínica, paciente de 28 anos relatou ter sofrido trauma dentário, no dente 21, durante prática esportiva na infância e sentia-se insatisfeita devido a frequente perda de retenção e falha estética apresentada pela restauração. Foi proposta a substituição da restauração por inserção direta, à mão livre, em resina composta, utilizando-se a estratificação ou técnica anatômica. O segundo relato de caso trata-se de paciente jovem, 14 anos, com fratura no dente 21 e restauração insatisfatória no dente 11. Optou-se pela técnica da moldagem, enceramento e reabilitação, utilizando-se guia de silicone. O terceiro caso clínico corresponde à paciente de 11 anos de idade, com fratura coronária do dente 11, com exposição pulpar. Entretanto, neste caso, o paciente apresentava-se com o fragmento dentário, sendo indicada a colagem. Pode se concluir que a escolha da técnica restauradora deve adequar-se às possibilidades e necessidades de cada paciente, sendo fundamental o conhecimento científico e habilidade do cirurgião dentista. Dentre as técnicas descritas neste artigo, todas apresentam resultados estéticos satisfatórios. A colagem do fragmento autógeno é fácil, rápida e conservadora, além de permitir a manutenção da textura, forma e propriedades ópticas e mecânicas originais.


Changes in beauty standards encourage people to seek dental treatment with a high excellence esthetic result. The aim of this article is to address different direct restorative techniques for anterior coronal fractured teeth, emphasizing advantages and disadvantages of clinical protocols. Thus, three case reports are discussed. In the first clinical situation, a 28 years-old patient suffered a dental trauma on the tooth 21 during sports practice in childhood. The patient was unsatisfied with the frequent loss of retention and esthetic failure presented by the restoration. It was proposed to replace it for free-hand direct insertion and composite resin using the layering or anatomical technique. The second clinical case is a fracture in tooth 21 and an unsatisfactory restoration in tooth 11 of a 14 years-old patient. The casting, waxing and rehabilitation techniques were chosen by using a silicone guide. The third clinical case was an 11 years-old patient with crown fracture in tooth 11 and pulp exposure. As the patient had the dental fragment, the bonding of it was indicated. It can be concluded that the choice of appropriate technique must consider the possibilities and needs of each patient, being fundamental both scientific knowledge and skill of the dentist. Among the techniques described in this article, all present satisfactory cosmetic results. The autogenous bonding of the fragment is easy, fast and conservative, and it allows the maintenance of texture, shape and unique optical and mechanical properties.

11.
Braz. dent. j ; 23(5): 484-489, Sept.-Oct. 2012. ilus, graf, tab
Article in English | LILACS | ID: lil-660348

ABSTRACT

This in vitro study analyzed the effect of different load application devices on fracture resistance and failure mode of maxillary premolars restored with composite resin. Sixty human maxillary premolars received standardized mesio-occluso-distal cavity preparations and were restored with composite resin. The specimens were randomly divided into 6 groups (n=10). Compressive loading was applied using 6 different metallic devices: S2: 2-mm sphere; S6: 6-mm sphere; C2: 2-mm cylinder; C6: 6-mm cylinder; WS: wedge shape device; and MAT: individualized metallic antagonist tooth. Data were analyzed statistically using one-way ANOVA and Tukey's test (α=0.05). The failure mode was recorded based on the 4 sequential levels. Statistical analysis revealed that WS presented significantly higher fracture resistance than S6 and C6. No significant difference was found among MAT, C2, S2 and S6. Sphere and cylinder with 6 mm were similar, with the lowest values of all groups. MAT presented the least number of catastrophic failures while C2, S2 and WS presented the highest. The type of load application device influences significantly the behavior of the teeth-restoration complex during mechanical fracture resistance test.


Este estudo avaliou o efeito de diferentes tipos de dispositivos de aplicação de carga na resistência à fratura de pré-molares superiores restaurados com resina composta. Sessenta pré-molares humanos receberam preparo mésio-ocluso-distal padronizado e as cavidades foram restauradas com resina composta. As amostras foram aleatoriamente divididas em 6 grupos (n=10). Carregamento de compressão foi realizado usando seis diferentes dispositivos metálicos de aplicação de carga: S2 e S6: esfera de 2 mm e 6 mm de diâmetro respectivamente; C2 e C6: cilindro de 2 mm e 6 mm de diâmetro respectivamente; WS: lâmina de faca e MAT: antagonista individualizado em metal. Os resultados foram submetidos à análise de variância e teste de Tukey (p<0,05). O modo de falha foi classificado em 4 níveis e estão apresentado em porcentagem. O dispositivo WS resultou em maior resistência a fratura de pré-molares que S6 e C6. Não houve diferença estatística entre os grupos MAT, C2, S2 e S6. Menor resistência foi verificada com o uso de S6 e C6. O dispositivo MAT resultou em menor número de falhas catastróficas enquanto nos grupos C2, S2 e WS essas falhas foram significativas. O tipo de dispositivo de aplicação de carga influenciou significativamente no comportamento do complexo dente-restauração durante o teste de resistência à fratura.


Subject(s)
Humans , Composite Resins/chemistry , Dental Restoration, Permanent , Equipment Failure Analysis/instrumentation , Materials Testing/instrumentation , Tooth Fractures , Analysis of Variance , Bicuspid , Equipment Failure Analysis/methods
12.
Braz. dent. j ; 23(2): 135-740, Mar.-Apr. 2012. tab
Article in English | LILACS | ID: lil-626301

ABSTRACT

In this survey, retrospective and prospective clinical studies dealing with cast-post-and core and fiber posts were reviewed regarding the rate of survival of restorations and the most prevalent failures. Electronic searches of the literature were performed in MEDLINE by crossing the key words: "Fiber post and clinical study", "Fiber post and clinical evaluation", "Cast post-and-core and clinical study", and "Root post and retrospective survival study". The cut-off dates were December 1990 through the end of December 2010. Review of literature showed that several interrelated biological, mechanical, and aesthetic factors are involved in the survival rate of restorative procedures in endodontically treated teeth, and post selection should fulfill and optimize these factors. Data based on long-term clinical studies are essential for the general practitioner when making clinical decisions. An adequate selection of teeth and post system must be made, and a minimal amount of existing tooth substance should be removed. A ferrule must be present for safe indication of the fiber posts. Fiber glass posts have demonstrated good survival in clinical studies, with similar performance to cast-post-and cores. Metallic posts have good clinical survival, but the associated failures are mostly irreversible, unlike what happens with the glass fiber posts.


O objetivo foi realizar revisão de estudos clínicos retrospectivos e prospectivos de pinos e núcleos metálicos e pinos de fibra em relação à taxa de sobrevivência e tipo de falhas prevalentes. A revisão de literatura foi realizada utilizando a base de dados MEDLINE com os seguintes termos para pesquisa: “Pino de fibra e estudo clínico”, “Pino de fibra e avaliação clínica”, “Pinos e núcleos metálicos e estudo clínico”, “Pinos intra-radiculares e estudo clínicos retrospectivos”. O período avaliado foi de Dezembro de 1990 até o final de Dezembro de 2010. Vários fatores biológicos, mecânicos e estéticos estão envolvidos na taxa de sobrevivência do procedimento restaurador de dentes tratados endodonticamente. A seleção do pino deve satisfazer e otimizar esses fatores. Dados com base em estudos clínicos de longo prazo são essenciais para o clínico geral na tomada de decisões. Adequada indicação na seleção do sistema de pino devem ser feitas. Adicionalmente, desgaste mínimo da estrutura dentária existente deve ser priorizado. A presença de férula deve estar presente para garantir e melhorar a previsibilidade de pinos de fibra. Pinos de fibra de vidro têm demonstrado boa sobrevivência em estudos clínicos, com desempenho semelhante aos pinos metálicos e núcleos moldados e fundidos. Retentores metálicos apresentam boa sobrevivência clínica, no entanto as falhas envolvidas são em sua maioria irreversíveis, ao contrário do que acontece com os pinos de fibra de vidro.


Subject(s)
Humans , Dental Restoration Failure , Post and Core Technique , Root Canal Therapy/methods , Tooth, Nonvital , Dental Materials , Dental Restoration Failure/classification , Equipment Failure , Treatment Failure
13.
Braz. dent. j ; 23(4): 403-408, 2012. ilus, tab
Article in English | LILACS | ID: lil-658018

ABSTRACT

Dental ceramics present excellent ability to reproduce the natural teeth regarding esthetic and biomechanics. Recently, due to the advancement of ceramic technology, metal-free restorations were developed. However, the traditional metal-ceramic restorations still present the requirements of high strength, long survival in the oral environment and favorable aesthetics. In this context, it is essential to know the specificity of each ceramic system available in order to apply it properly to various clinical situations. This report describes an integrated rehabilitation using metal-ceramic restorations of a patient at 50 years of age, who presented edentulous spaces, and previous unsatisfactory composite and amalgam restorations, and indirect metallic restorations, leading to compromised quality of life in both functional and psychosocial aspects. The impact on quality of life was measured using a generic instrument, OHIP-14, validated for the World Health Organization, which covers both the biological and the psychosocial dimensions. This instrument was applied to the patient before and after treatment. The patient had an overall OHIP-14 score of 28 before the treatment and after treatment the score decreased to 0, showing that dental and oral health conditions are factors that do impact on the quality of life. Rehabilitation has provided functional and aesthetic restorations, harmony of the stomatognathic system and improvement of life quality.


As cerâmicas dentais são conhecidas pela excelência em reproduzir artificialmente dentes naturais. Recentemente, devido ao aprimoramento da tecnologia cerâmica, surgiram as restaurações livres de metal. Entretanto, as tradicionais metalocerâmicas ainda preenchem adequadamente os requisitos de alta resistência, longa sobrevida em meio bucal e estética favorável. Neste contexto, é fundamental conhecer a especificidade de cada sistema cerâmico a fim de indicá-lo adequadamente às diversas situações clínicas. Este artigo relata um caso de reabilitação integral e integrada de paciente de 50 anos de idade, portador de espaços edêntulos, restaurações protéticas posteriores e restaurações diretas anteriores insatisfatórias, resultando em comprometimento da qualidade de vida nos âmbitos funcional e psicossocial, utilizando coroas metalocerâmicas. O impacto na qualidade de vida foi mensurado utilizando um instrumento genérico, OHIP-14, validado pela Organização Mundial de Saúde, que abrange tanto a dimensão biológica, como a dimensão psicossocial. Este instrumento foi aplicado à paciente antes e após o tratamento, obtendo pontuação total de 28 e 0 respectivamente, o que mostra que a condição de saúde oral representa fator de grande impacto sobre a qualidade de vida. A reabilitação oral proporcionou restabelecimento funcional e estético, harmonia do sistema estomatognático e melhoria da qualidade de vida da paciente.


Subject(s)
Female , Humans , Middle Aged , Dental Porcelain/chemistry , Denture Design/psychology , Metal Ceramic Alloys/chemistry , Mouth Rehabilitation/psychology , Oral Health , Quality of Life , Attitude to Health , Anti-Bacterial Agents/adverse effects , Dental Restoration Failure , Follow-Up Studies , Facial Pain/rehabilitation , Gingivoplasty/methods , Patient Care Planning , Patient Satisfaction , Smiling , Surgical Flaps/surgery , Tetracycline/adverse effects , Tooth Discoloration/chemically induced , Tooth Discoloration/rehabilitation , Vertical Dimension
14.
Perionews ; 5(4): 403-408, jul.-ago. 2011. ilus
Article in Portuguese | LILACS | ID: lil-688103

ABSTRACT

A inter-relação entre as diversas áreas da Odontologia é importante no restabelecimento estético e funcional de dentes com grandes perdas estruturais O desenvolvimento e a utilização de materiais que mimetizem as características mecânicas dos tecidos dentários têm se tornado muito frequentes, com o intuito de preservar a integridade das estruturas dentárias remanescentes. 0 tracionamento ortodôntico na região anterior tem sido cada vez mais empregado para devolver biologia e estética dessa região. Em casos clínicos onde a estética é fundamental, deve-se integrar a estética dental com a gengival. 0 objetivo deste relato de caso clínico foi mostrar como as diferentes áreas da Odontologia podem trabalhar juntas no planejamento e na resolução de alterações estéticas e funcionais da cavidade oral causada por traumatismos dentários, obtendo-se excelência estética com satisfação mútua, do profissional e do paciente.


Subject(s)
Humans , Male , Young Adult , Ceramics , Dental Pins , Esthetics, Dental , Orthodontics , Periodontics , Smiling
15.
Rev. Assoc. Paul. Cir. Dent ; 65(1): 60-64, jan.-fev. 2011.
Article in Portuguese | LILACS, BBO | ID: lil-590236

ABSTRACT

o tratamento endodôntico em dentes com grande destruição coronária é um procedimento clínico comum no cotidiano das clínicas odontológicas. Na maioria destas situações clínicas, há a indicação do uso de retentor intrarradicular para dar estabilidade e retenção à restauração. Uma das técnicas propostas para o tratamento de canais amplos é a utilização de um pino de fibra de vidro com módulo de elasticidade próximo ao da dentina, remodelado com resina composta para preencher o espaço existente no canal radicular alargado. Esta técnica reduz quantidades excessivas de cimento que serviriam para substituir a estrutura dental perdida e permite uma boa adaptação no conduto radicular, criando condições favoráveis para retenção do pino. O objetivo deste trabalho foi demonstrar a técnica de anatomização de pinos intrarradiculares estéticos com resina composta, em incisivo anterior com grande destruição coronária. A utilização de um pino de fibra de vidro anatômico foi a alternativa indicada para a resolução clínica de forma a proteger o remanescente dental enfraquecido, além de obter estética aliada a um prognóstico favorável.


Root canal therapy in teeth with large coronal destruction is a common clinical precedure in the daily dental clinics. In most of these conditions, there is an indication of the use of intra-radicular post for stability and retention for the restoration. One of the techniques proposed for the treatment of enlarged channels, is the use of a fiber glass with modulus of elasticity similar to dentin, restored with composite resin to fill the space between the root canal extended. This technique reduces excessive amounts of cement that would serve to replace the lost tooth structure and allows a good adaptation in the root canal, creating favorable conditions for retention of the post. The objective was to demonstrate the technique of anatomization intraradicular aesthetic post with composite resin in anterior incisor with large coronal destruction. The use of a fiber glass anatomical was the alternative used for clinical resolution in order to reinforce the remaining tooth structure weakened, returning him to function without requiring the removal of sound tooth structure, and aesthetics combined with a more favorable prognosis.


Subject(s)
Humans , Male , Female , Ceramics/therapeutic use , Resin Cements/therapeutic use , Dental Pins , Composite Resins/therapeutic use
16.
Braz. dent. j ; 22(3): 230-237, 2011. ilus, tab
Article in English | LILACS | ID: lil-595646

ABSTRACT

Restoring flared endodontically treated teeth continues to be a challenge for clinicians. This study evaluated the effect of post types and restorative techniques on the strain, fracture resistance, and fracture mode of incisors with weakened roots. One hundred five endodontically treated bovine incisors roots (15 mm) were divided into 7 groups (n=15). The two control groups were (C) intact roots restored with Cpc (cast posts and core) or Gfp (glass fiber posts). The five experimental groups were (F) flared roots restored with GfpAp (Gfp associated with accessory glass fiber posts), GfpRc (anatomic Gfp, relined with composite resin), and GfpRcAp (anatomized Gfp with resin and accessory glass fiber posts). All teeth were restored with metal crowns. Mechanical fatigue was performed with 3x10(5)/50 N. Specimens were loaded at 45º, and the strain values (μS) were obtained on root buccal and proximal surfaces. Following that, the fracture resistance (N) was measured. One-way ANOVA and Tukey's HSD tests (α=0.05) were applied, and failure mode was checked. No significant difference in strain values among the groups was found. Cpc presented lower fracture resistance and more catastrophic failures in flared roots. Gfp associated with composite resin or accessory glass fiber posts seems to be an effective method to improve the biomechanical behavior of flared roots.


Restaurar dentes tratados endodonticamente continua sendo desafio para clínicos. Este estudo avaliou o efeito de pinos e técnicas na deformação, resistência à fratura e padrão de fratura de incisivos com canal radicular alargado. Cento e cinco raízes bovinas, tratadas endodonticamente (15 mm) foram divididas em 7 grupos (n=15). Os grupos controle (C), constituídos de raízes não alargadas, foram restauradas com Cpc (núcleo metálico fundido) ou Gfp (pino de fibra de vidro). Nos grupos experimentais os canais foram alargados (F) e restaurados com: GfpAp (Gfp associado com pinos de fibra de vidro acessórios); GfpRc (pino anatômico, reembasado com resina composta) e GfpRcAp (pino anatomizado com resina composta e pinos acessórios). Os dentes foram restaurados com coroas metálicas. Fadiga mecânica foi simulada com 3x10(5)/50 N ciclos. O teste foi realizado a 45º e a deformação (μS) obtida nas superfícies vestibular e proximal. Em seguida, a resistência à fratura (N) e o padrão de fratura foram verificados. Aplicou-se ANOVA e Teste de Tukey (α=0,05). Não houve diferença na deformação. Cpc resultou em menor resistência à fratura e com mais fraturas catastróficas em raízes fragilizadas. As técnicas de reembasamento do pino com resina composta ou o uso de pinos acessórios parecem ser efetivos para melhorar o comportamento biomecânico de raízes fragilizadas.


Subject(s)
Animals , Cattle , Dental Prosthesis Design , Incisor/physiopathology , Post and Core Technique/instrumentation , Tooth Fractures/physiopathology , Tooth Root/physiopathology , Tooth, Nonvital/therapy , Biomechanical Phenomena , Crowns , Chromium Alloys/chemistry , Composite Resins/chemistry , Dental Restoration Failure , Dental Materials/chemistry , Dental Pulp Cavity/pathology , Dental Stress Analysis/instrumentation , Dentin-Bonding Agents/chemistry , Dentin/pathology , Epoxy Resins/chemistry , Glass/chemistry , Incisor/pathology , Random Allocation , Resin Cements/chemistry , Root Canal Preparation/methods , Stress, Mechanical , Silanes/chemistry , Tooth Fractures/classification , Tooth Root/pathology
17.
Braz. j. pharm. sci ; 46(3): 585-595, July-Sept. 2010. ilus
Article in English | LILACS | ID: lil-564927

ABSTRACT

The treatment of diseases affecting the posterior segment of the eye is limited by the difficulty in transporting effective doses of drugs to the vitreous, retina, and choroid. Topically applied drugs are poorly absorbed due to the low permeability of the external ocular tissues and tearing. The blood-retina barrier limits drug diffusion from the systemic blood to the posterior segment, thus high doses of drug are needed to maintain therapeutic levels. In addition, systemic side effects are common. Intraocular injections could be an alternative, but the fast flowing blood supply in this region, associated with rapid clearance rates, causes drug concentration to quickly fall below therapeutic levels. To obtain therapeutic levels over longer time periods, polymeric sustained-drug release systems implanted within the vitreous are being studied for the treatment of vitreoretinal disorders. These systems are prepared using different kinds of biodegradable or non-biodegradable polymers. This review aims to demonstrate the main characteristics of these drug delivery implants and their potential for clinical application.


O tratamento de doenças do segmento posterior do olho é limitado pela dificuldade no transporte de doses efetivas de fármacos para o vítreo, retina e coróide. Os fármacos aplicados topicamente são pouco absorvidos por causa da baixa permeabilidade dos tecidos oculares externos e ao lacrimejamento. Embora a administração sistêmica seja capaz de transportar fármacos para o segmento posterior do olho, as barreiras hemato-aquosa e hematorretiniana dificultam a absorção e, normalmente, são necessárias doses elevadas, as quais estão geralmente associadas a potenciais efeitos adversos. Injeções intravitreais são capazes de transportar fármacos para o segmento posterior do olho, mas é uma técnica invasiva, pouco tolerada pelos pacientes e apresenta riscos de infecções oculares e danos aos tecidos. Visando a obtenção de níveis terapêuticos adequados de fármacos no segmento posterior do bulbo do olho por longos períodos, sistemas de liberação poliméricos implantados diretamente no vítreo estão sendo investigados para o tratamento de várias doenças vítreo-retinianas. Esses implantes podem ser preparados a partir de diferentes polímeros biocompatíveis, biodegradáveis ou não-biodegradáveis. Nesta revisão, as principais características destes implantes transportadores de fármacos são descritas, expondo suas potencialidades de aplicação clínica.


Subject(s)
Chemistry, Pharmaceutical , Drug Implants/chemistry , Eye Diseases/drug therapy , Therapeutics/methods , Polyvinyl Alcohol/therapeutic use , Retinitis , Technology, Pharmaceutical
18.
Braz. dent. j ; 21(3): 235-240, 2010. ilus, tab
Article in English | LILACS | ID: lil-556824

ABSTRACT

This study evaluate the use of bovine teeth as a substitute for human teeth on fracture strength tests of composite fixed partial dentures (Cpd), with and without fiberglass reinforcement (Fg). Eighty teeth were selected, being 40 bovine incisors, 20 human premolars and 20 molars. Bovine incisors were ground to get a platform, simulating an occlusal surface of human molar. Teeth in pairs were embedded in polystyrene resin, simulating the periodontal ligament and divided in 4 groups: B-Cpd-Fg: bovine teeth restored with Cpd with Fg; B-Cpd-NFg: bovine teeth restored with Cpd without Fg; H-Cpd-Fg: human teeth restored Cpd with Fg; and H-Cpd-NFg: human teeth restored with Cpd without Fg. The Cpd were adhesively fixed and submitted to an axial compression load at the pontic center with a crosshead speed of 0.5 mm/min until fracture. Failure modes were assessed and classified. Data were subjected to two-way ANOVA and Tukey's HSD test (?=0.05). The tooth type had no influence on fracture strength and fracture mode. The inclusion of fiberglass increased significantly the fracture strength. The failure modes were more reparable in groups with fiber-reinforcement. Bovine teeth can be used as a substitute for human teeth in these types of fracture strength tests.


Este estudo avaliou a utilização de dentes bovinos como substituto de dentes humanos em testes de resistência à fratura de próteses adesivas de resina composta (Cpd), com e sem fibra de reforço. Oitenta dentes foram selecionados sendo 40 incisivos bovinos, 20 pré-molares humanos e 20 molares. Incisivos bovinos foram desgastados para obter plataforma, simulando superfície oclusal de molares humanos. Dentes em pares foram incluídos em resina de poliestireno, simulando o ligamento periodontal. As amostras foram divididas em 4 grupos: B-Cpd-Fg, dentes bovinos restaurados com reforço de fibra de vidro, Fg; B-Cpd-NFg, dentes bovinos restaurados com Cpd sem Fg; H-Cpd-Fg, dentes humanos restaurados com Cpd Fg e H-Cpd-NFg, dentes humanos restaurados com Cpd sem Fg. O Cpd foi fixado adesivamente e submetido a carga de compressão axial no centro do pôntico com velocidade de 0,5 mm/min até a fratura. Padrões de fratura foram classificados. Os dados foram submetidos ANOVA fatorial e teste de Tukey HSD (?=0,05). O tipo de dente não teve nenhuma influência na resistência à fratura e modo de fratura. A inclusão de fibra de vidro aumentou significativamente a resistência à fratura. Os padrões de fratura foram mais reparáveis nos grupos com fibra de reforço. Os dentes bovinos podem ser usados como substituto para dentes humanos nesses tipos de testes de resistência à fratura.


Subject(s)
Animals , Cattle , Humans , Dental Restoration Failure , Denture Design , Denture, Partial, Fixed, Resin-Bonded , Dental Stress Analysis/methods , Analysis of Variance , Compressive Strength , Denture Bases , Dental Stress Analysis/instrumentation , Glass , Statistics, Nonparametric
19.
J. appl. oral sci ; 17(2): 140-144, Mar.-Apr. 2009. ilus
Article in English | LILACS | ID: lil-503993

ABSTRACT

The esthetic and functional rehabilitation of patients with multiple missing teeth can be performed with several techniques and materials. Ceramic restorations provide reliable masticatory function and good esthetics. However, fracture can occur in some cases due to their brittle behavior. In some cases, the replacement of an extensive prosthesis is a problem due to the high treatment cost. In this paper, two cases are presented, in which fractures occurred in extensive metal-ceramic fixed partial dentures, and their replacement was not possible. Ceramic repair was chosen and the sequences of treatment with and without presence of the ceramic fragment are also discussed. The cases illustrate that, in some situations, fractured metal-ceramic partial dentures can be successfully repaired when prosthetic replacement is not a choice. Prosthodontists must use alternatives that allow a reliable repair to extensive metal-ceramic fixed partial dentures. Surface preparation of the ceramic with hydrofluoric acid in conjunction with a silane coupling agent is essential for a predictable bonding of composite resin. The repair performed with composite resin is an esthetic and functional alternative when extensive fixed partial dentures cannot be replaced.


Subject(s)
Female , Humans , Middle Aged , Dental Porcelain , Denture, Partial, Fixed , Denture Repair/methods , Acid Etching, Dental , Composite Resins , Dental Bonding/methods , Metal Ceramic Alloys , Resin Cements , Silanes
20.
ROBRAC ; 15(39): 44-50, jun. 2006. tab, ilus
Article in Portuguese | LILACS-Express | LILACS | ID: lil-527923

ABSTRACT

Este estudo avaliou a influência da confecção da canaleta e posterior restauração com resina composta, na resistência de união da colagem de fragmento dental. Quarenta incisivos bovinos foram fraturados a 3 mm da junção cemento-esmalte e divididos em 4 grupos (n=10) nos quais a colagem do fragmento foi realizada com cimento resinoso dual após hibridização das superfícies de adesão. No grupo 1, foi feita somente a colagem, sem preparo adicional. Nos outros grupos as canaletas (0.7mm de profundidade)foram feitas e restauradas sobre a linha de união com diferentes localizações. Grupo 2, canaleta na facevestibular; grupo 3, canaleta na face lingual; grupo 4, canaleta nas faces vestibular e lingual. As amostras foram testadas usando dispositivo em forma de faca em máquina de ensaio mecânico(0.5mm/min) num ângulo de 90 na face lingual. Os valores em Kgf foram submetidos à análise estatística (?=0.05) e o teste de Kruskall-Wallis não mostrou diferença significativa entre os grupos (p=0.565)...


The effect of the chamfer and posterior restoration using composite resin on the bond strength of dental reattachment was evaluated. Forty bovine teeth were fractured 3 mm above the cement-enamel junction, divided in 4 groups (n=10) and the fragments were reattached with a dual resin cement afterhybridization of the bonding surfaces. In the group 1 the reattachment was done without additional preparation but in the other groups chamfers (0.7 mm depth) were made and restored with composite resin along the bond line in different locations. Group 2, chamfer on the buccal aspect; group 3, chamferon the lingual aspect; group 4, chamfer on both buccal and lingual aspects. Specimens were sheared using a spade blade in a test machine (0.5 mm/min) at 90° to the lingual surface. The data (Kgf) were submitted to statistical analysis (?=0.05) and the Kruskall-Wallis test showed no significant differences among the groups (p=0.565)...

SELECTION OF CITATIONS
SEARCH DETAIL